Skip to content

Testing Redis Sentinel failover without breaking production

Build a regular failover-drill routine for Sentinel-managed Redis: planned failover, kill-the-master tests, client-side validation, and the metrics to watch.

The reason teams hit a real Sentinel failover and watch the recovery take three minutes instead of ten seconds is that nobody had tested it since deployment. Failover testing is a runbook with a fixed cadence — a planned SENTINEL failover, a kill-the-process test, and a network-partition simulation. This article is the playbook we use to prove Sentinel-managed Redis topologies are still failing over the way they should.

How to verify

# Baseline: what should happen?
redis-cli -p 26379 SENTINEL get-master-addr-by-name mymaster
redis-cli -p 26379 SENTINEL replicas mymaster | grep -E 'name|ip|port'
redis-cli -p 26379 SENTINEL ckquorum mymaster
# Expected: "OK 3 usable Sentinels. Quorum and failover authorization can be reached"

# Timing baseline — set this as the SLO
redis-cli -h current-master -a "$PASS" --latency-history -i 1 &
LATPID=$!
date +%s
# ... trigger failover ...
date +%s
kill $LATPID

What’s happening

A failover test has three goals:

  1. Confirm Sentinel still elects a new master. Quorum unchanged, replicas reachable, no network drift since the last test.
  2. Measure failover time. From the moment the master goes away to the moment clients write again. The SLO is typically 5-15 seconds depending on down-after-milliseconds.
  3. Verify client behavior. A Sentinel-aware client should drop connections to the old master, learn the new one via subscription to +switch-master, and resume traffic without code-level errors. A misconfigured client gets stuck.

There are three test modes, ordered from gentle to invasive:

  • Planned failover. SENTINEL failover mymaster triggers an orderly switch with the old master gracefully demoted. Zero data loss, validates the election and replica selection.
  • Kill-the-process. kill -9 <redis-pid> on the master. Triggers the natural detection cycle (subjective down → quorum → election → promotion). Validates the timeout settings and full path under crash.
  • Network partition. Drop traffic to the master with iptables -A INPUT -p tcp --dport 6379 -j DROP or by isolating the host’s network interface. Validates Sentinel’s ability to detect a master that is “alive” but unreachable.

The right cadence in production: planned failover once a month, kill-the-process once a quarter on a staging clone, network partition once a quarter where infrastructure allows it.

The procedure

  1. Pre-flight checks. Quorum reachable, replication healthy, backups recent:

    redis-cli -p 26379 SENTINEL ckquorum mymaster
    redis-cli -h current-master -a "$PASS" INFO replication | grep -E 'role|connected_slaves|repl_backlog_active'
    redis-cli -h current-master -a "$PASS" LASTSAVE

    If any of these fails, abort the test — fix the underlying issue first.

  2. Start a latency probe from the application network:

    redis-cli -h sentinel-aware-vip -a "$PASS" --latency-history -i 1 > /tmp/latency.log &
  3. Mark the test in monitoring. Add an annotation in Grafana / pagerduty so spikes are not misread as a real incident.

  4. Trigger a planned failover. From any sentinel:

    redis-cli -p 26379 SENTINEL failover mymaster
    # Returns: OK

    Watch the sentinel log:

    sudo journalctl -u redis-sentinel -f | grep -E '\+switch-master|\+slave-reconf-done'
  5. Measure recovery time. From the SENTINEL failover timestamp to the +switch-master event should be under 10 seconds on a healthy topology. The latency probe should show a few seconds of Could not connect to Redis then resume.

  6. Validate client behavior. Watch your application’s metrics — error rate during the failover window. A well-behaved client shows a small spike of failed requests and then normal traffic. A misconfigured client shows persistent errors and needs manual intervention.

  7. Run the kill-test on staging. SSH to the master, find the PID, kill it ungracefully:

    PID=$(pgrep -f "redis-server.*6379")
    sudo kill -9 "$PID"
    date +%s

    Recovery time is down-after-milliseconds + election + promotion — should match within 1-2 seconds of the planned-failover test.

  8. Recover the killed master. It comes up, discovers via Sentinel that it should be a replica, and resyncs. Verify:

    redis-cli -h previous-master -a "$PASS" INFO replication
    # role:slave
    # master_link_status:up
  9. Document the timings in a runbook entry. Outcome, recovery time, anything that changed since the last drill. Drift between drills is the warning.

Common pitfalls

  • A drill that succeeds but takes 3x longer than the previous one means something has degraded — network, Sentinel reachability, replica health. Investigate before declaring success.
  • A planned failover during peak load is risky for the wrong reason: not because the failover is unsafe, but because the latency hit during the gap is more visible. Schedule for off-peak.
  • The latency probe must come from the application network, not from the Redis host. Probing from the same host masks the failover-window outage.
  • A test on staging that does not mirror production’s down-after-milliseconds and failover-timeout tells you nothing about production timing.
  • After a kill-test, the old master may need its replicaof line cleared from redis.conf if slaveof was written explicitly — Sentinel handles this automatically via the runtime config, but a manual redis.conf clears the line and the post-test recovery loops.

In the engagements we run, every Sentinel-managed Redis has a calendar entry for a monthly planned failover, a quarterly kill-test in staging, and a Prometheus alert if +switch-master events have not been seen in 35 days (drill drift). We operate that under Managed Operations — and the underlying mechanism is detailed in Sentinel deep dive.