Skip to content

Rails deployment with Passenger or Puma

Pick between Phusion Passenger and Puma for a Rails app server, configure either behind Nginx, and tune workers and threads for the workload.

A Rails app needs an app server in front of Nginx, and the two real choices are Phusion Passenger and Puma. They occupy different operational shapes — Passenger is closer to PHP-FPM (Nginx integration, declarative config, multi-app support); Puma is closer to Gunicorn (per-app process you supervise yourself). This article walks through both, then helps you pick.

How to verify

Inspect what’s running today:

systemctl status puma-app 2>/dev/null | head
sudo nginx -T 2>/dev/null | grep -E 'passenger|puma|unicorn' | head
ls /etc/nginx/conf.d/*passenger* 2>/dev/null
sudo lsof -iTCP:3000 -sTCP:LISTEN 2>/dev/null
ps -eo pid,etime,cmd | grep -E "puma|passenger|unicorn" | head

If both Passenger and a Puma systemd unit appear, an in-progress migration was left half-done — pick one and remove the other before tuning.

What’s happening

Passenger is a hybrid Nginx module and standalone server. With the Nginx-integrated install, Nginx itself spawns Ruby workers through Passenger — the configuration is passenger_enabled on; in a server block plus passenger_app_root. Passenger manages its own process pool, exposes statistics, and handles multi-tenancy (multiple Rails apps on one Nginx instance share Passenger).

Puma is a pure Ruby app server with a primary process and worker children. It listens on a TCP port or UNIX socket, and Nginx connects to it like any HTTP upstream. Puma is what Rails generates by default since Rails 5. It is multi-process (workers) plus multi-threaded (threads); workers are forks of the master, threads share memory within a worker.

The shape of the workload changes which model wins. CPU-bound Rails apps benefit from more workers (and fewer threads), because the GVL serializes Ruby execution within a worker. I/O-bound Rails apps (lots of DB or external HTTP) benefit from more threads per worker, because threads pick up work while the GVL is released around I/O. The 5 workers × 5 threads default is a reasonable starting point but it is just a default.

Decision

  1. Pick Puma if you have one Rails app per host, want full control of the systemd unit, or are following the Rails defaults. Most modern Rails deployments choose Puma.

  2. Pick Passenger if you have multiple Rails apps on one host (it shares a process pool across them, smaller memory footprint), need the runtime stats dashboard, or already operate Passenger and have the staff comfort with it.

  3. Configure Puma by editing config/puma.rb in the Rails app:

    max_threads_count = ENV.fetch("RAILS_MAX_THREADS", 5).to_i
    min_threads_count = ENV.fetch("RAILS_MIN_THREADS", max_threads_count).to_i
    threads min_threads_count, max_threads_count
    
    workers ENV.fetch("WEB_CONCURRENCY", 4).to_i
    preload_app!
    
    bind "unix:///run/puma/app.sock"
    pidfile "/run/puma/app.pid"
    state_path "/run/puma/app.state"
    
    plugin :tmp_restart
    
    on_worker_boot do
      ActiveRecord::Base.establish_connection if defined?(ActiveRecord)
    end

    preload_app! with on_worker_boot reconnecting AR is the standard pattern — saves memory via copy-on-write, but requires re-establishing per-worker resources.

  4. The systemd unit for Puma. /etc/systemd/system/puma-app.service:

    [Unit]
    Description=Puma for app
    After=network.target
    
    [Service]
    User=deploy
    Group=www-data
    WorkingDirectory=/var/www/app/current
    RuntimeDirectory=puma
    Environment=RAILS_ENV=production
    ExecStart=/home/deploy/.rbenv/versions/3.3.6/bin/bundle exec puma -C config/puma.rb
    ExecReload=/bin/kill -USR1 $MAINPID
    KillMode=mixed
    Restart=on-failure
    
    [Install]
    WantedBy=multi-user.target

    ExecReload=/bin/kill -USR1 is Puma’s phased restart signal — workers are recycled one at a time without dropping connections, but only if preload_app! is off. With preload_app!, only USR2 (full restart) works.

  5. Nginx in front, pointing at the Puma UNIX socket:

    upstream puma_app {
      server unix:/run/puma/app.sock fail_timeout=0;
    }
    
    server {
      listen 443 ssl http2;
      server_name app.example.com;
      # ... ssl_certificate etc.
    
      root /var/www/app/current/public;
      try_files $uri @app;
    
      location @app {
        proxy_pass http://puma_app;
        proxy_set_header Host $host;
        proxy_set_header X-Real-IP $remote_addr;
        proxy_set_header X-Forwarded-For $proxy_add_x_forwarded_for;
        proxy_set_header X-Forwarded-Proto https;
      }
    }

    Static files in public/ are served directly by Nginx — Puma never sees those requests.

Operational notes

  • Puma’s phased-restart only works without preload_app!. Without preload, each worker boot pays the full Rails boot cost (~5-10 s per worker) — that adds up if you have many workers, but the rolling restart is the trade-off.
  • Memory leaks in Rails are common (long-lived ActiveRecord connections, instance variables on singletons). Tools like puma-killer and puma_worker_killer recycle workers at memory thresholds or request counts — analogous to PHP-FPM’s pm.max_requests.
  • Passenger’s passenger_min_instances and passenger_max_pool_size are the equivalents of workers in Puma. The big difference is Passenger spins up workers on demand and idles them down; Puma keeps the set you configured.
  • With both servers, the Rails connection pool (pool: 5 in database.yml) must be at least as large as threads per worker. If threads = 5 and pool = 3, threads will block waiting for connections under load.
  • Test the deploy with kill -USR1 $MAINPID (phased) and kill -USR2 $MAINPID (full) once before relying on either in a real release script — Puma’s signal handling has changed across versions.

For the rbenv install backing this, see Installing Ruby with rbenv. Stack Harbor’s managed operations practice deploys Rails on Puma + Nginx as the default for single-app hosts, switching to Passenger only when multi-tenancy or staff familiarity dictates — the choice is about the operating shape, not which one is “better”.